Partition Walls for Airborne and Impact Noise
in Premises with High Noise Levels

SENOR-TAV-500/ 11 A


Video installation of a high-performance acoustic plasterboard partition – cinemas, theaters, pubs, nightclubs, and venues.

Patented
Acoustic plug designed for the total decoupling of a C-type self-supporting structure or channel from the floor slab
Model TAV-500/11 A
We are pleased to introduce the essential acoustic fixing designed to eliminate solid-borne noise pollution. This solution integrates advanced technology featuring a new polymeric component developed by the prestigious German manufacturer KRAIBURG. The material has been precision-engineered to provide greater peace of mind, comfort, and environmental quality in environments where impact noise and vibrations can cause annoyance, impair concentration, or compromise occupant well-being. We have completely redesigned the product to meet contemporary demands for acoustic performance, comfort, and construction quality, delivering an effective solution seamlessly integrated into the fixing system.
Its innovative design incorporates targeted technology to mitigate pollution generated by vibromechanical energy, preventing unnecessary transmission into walls, floor slabs, and other adjacent structural elements. By restricting these transmission paths, the fixing helps break acoustic bridges and reduce structural vibration propagation, fostering cleaner, quieter, and more pleasant spaces. In doing so, it enhances the overall acoustic quality of the environment and delivers a more comfortable experience for building occupants.
The acoustic plug SE-TAV-500/11 A features a PATENTED motion control system that isolates any type of fixing, including the screw, from the rest of the drywall/construction system materials. This controlled separation breaks acoustic bridges and helps eradicate vibromechanical transmission through connection points. As a result, airborne noise has been reduced by more than 16 dBA within a previously tested and certified drywall system—a result that demonstrates its direct contribution to enhancing acoustic comfort and minimizing noise disturbance in the built environment.
The SE-TAV-500/11 A acoustic plug is engineered for placement in horizontal floor channels and vertical studs intended for attachment to existing masonry walls. Its purpose is to enhance the acoustic performance of these junctions by promoting proper separation and suppressing vibration and noise transmission through the structure. For further details regarding specifications, application, and installation guidelines, click on «Download technical sheet».
- TAV-500 11/A: in lower U-channels and vertical studs
Installation video
Rubber plug for decoupling the metal screw from the rest of the materials
Product registered in the Spanish Patents and Trademarks Office
It avoids vibration transmission between building’s original walls and wall partition or wall lining system
It provides an excellent soundproofing
Together with acoustic rubber strip provides acoustic and thermal sealing to the partition wall or wall lining system
Together with wall mounts the maximum elasticity is obtained


Box format:
– SE-TAV-500/11A-12: 12 units
Test Report Nº: B2021-LACUS-IN-159 A
Purpose: Airborne Soundproofing Test
Standards: UNE-EN ISO 10140-1:2016 and 10140-2:2011
Laboratory: TECNALIA (Vitoria, SPAIN)
Date: 30 November 2021
Sample: CHOVA+SENOR SELF-SUPPORTING ACOUSTIC WALL LINING – EI120
Standardised Base Wall: 15 cm concrete block + plasterboards on both sides
Standardised Base Thickness and Weight: 17.5 cm and 300 kg/m²
Total Wall Lining Thickness: 20.2 cm
Sample Description: Self-supporting wall lining system comprising: SE-4800/TDM dampers (SENOR) + SE-TAV-500/11A and 11R acoustic plugs (SENOR) + SE-BEC-10×100 acoustic strip (SENOR) + 48 mm channels and studs (KNAUF) + SE-MONT-BICAPA-40 decoupling strip (SENOR) + 4 cm CHOVANAPA sound-absorbing material (CHOVA) + 25 mm Fireproof Plasterboard (KNAUF) + 4 mm VISCOLAM 65 acoustic membrane (CHOVA) + 25 mm Fireproof Plasterboard (KNAUF)
Note: The soundproofing results obtained in this test are also valid for the TAV/500 11 A product, as both products share the same properties
Result: An improvement of 21 dB in airborne sound compared to the base wall, which has a rating of 48 dB, resulting in a total soundproofing of 70 dB.
Laboratory measurement of airborne sound insulation improvement – WITH DAMPERS –
Test Report Nº: B2020-LACUS-IN-122-2 A
Purpose: Airborne Soundproofing Test
Standards: UNE-EN ISO 10140-1:2016 and 10140-2:2011
Laboratory: TECNALIA (Vitoria, SPAIN)
Date: 23 October 2020
Sample: CHOVA+SENOR SELF-SUPPORTING ACOUSTIC WALL LINING
Standardised Base Wall: 15 cm concrete block + plasterboards on both sides
Standardised Base Thickness and Weight: 17.5 cm and 300 kg/m²
Total Wall Lining Thickness: 19.5 cm
Sample Description: Self-supporting wall lining system comprising: SE-3802/03 TD1 dampers (SENOR) + SE-TAV-500/11A and 11R acoustic plugs (SENOR) + SE-BEC-10×100 and SE-BEC-6×100 acoustic strips (SENOR) + 48 mm channels and studs (KNAUF) + SE-MONT-BICAPA-40 decoupling strip (SENOR) + 4 cm CHOVANAPA sound-absorbing material (CHOVA) + 15 mm Plasterboard (KNAUF) + 4 mm VISCOLAM 65 acoustic membrane (CHOVA) + 12.5 mm Plasterboard (KNAUF).
Note: The soundproofing results obtained in this test are also valid for the TAV/500 11 A product, as both products share the same properties
Result: An improvement of 17 dB in airborne sound compared to the base wall, which has a rating of 48 dB, resulting in a total soundproofing of 65 dB.
Laboratory measurement of airborne sound insulation improvement – WITH DAMPERS –
Laboratory measurement of airborne sound insulation improvement – WITHOUT DAMPERS –
Test report No: 110924-637 A
Objet: Airborne Noise Insulation Test
Standar: UNE-EN ISO 10140-2:2022
Laboratory: TECNALIA (Vitoria)
Date: JUNE 14th, 2024
Sample: ACOUSTIC PARTITION WALL WITH MAXIMUM AIRTIGHTNESS URSA+SENOR
Sample dimensions: 3.6 m long x 2.8 m wide = 10,08 m²
Estimated mass: 41 kg/m²
Total partition wall thickness: 11 cm
Description of the sample: acoustic partition wall with simple self-supporting structure formed with dampers SE-TMT-50 R (SENOR) + acoustic plugs SE-TAV-500/11A and 11R (SENOR) + acoustic strip SE-BEC (SENOR) all around the perimeter + 48 mm channels and studs (KNAUF) + decoupling strip SE-MONT-BICAPA-40 (SENOR) on both sides + mineral wool TERRA PLUS 32 (URSA) + 2 standard PYL of 12, 5 mm standard PYL (KNAUF) on each side + acoustic membrane M.A.D.4 on one side between the boards
Note: The soundproofing results obtained in this test are also valid for the TAV/500 11 A product, as both products share the same properties
Result: 42 dB total isolation
Test Report No: 110923-638 A
Objet : Airborne Noise Insulation Test
Standar: UNE-EN ISO 10140-2:2022
Laboratory: TECNALIA (Vitoria)
Date: JUNE 19th, 2024
Sample: URSA+SENOR ACOUSTIC PARTITION WITH LOSS OF AIRTIGHTNESS
Sample dimensions: 3.6 m long x 2.8 m wide = 10,08 m²
Estimated mass: 41 kg/m²
Total partition wall thickness: 11 cm
Sample description: acoustic partition wall with simple self-supporting structure formed with dampers SE-TMT-50 R (SENOR) + 7 cm SE-BEC (SENOR) tongues + acoustic plugs SE-TAV-500/11A and 11R (SENOR) + acoustic strip SE-BEC (SENOR) on sides and ceiling + 48 mm channels and studs (KNAUF) + decoupling strip SE-MONT-BICAPA-40 (SENOR) on both sides + mineral wool TERRA of 12, 5 mm TERRA mineral wool (KNAUF) on each side + acoustic membrane M.A.D.4 on one side between the boards.
Note: The soundproofing results obtained in this test are also valid for the TAV/500 11 A product, as both products share the same properties
Result: 26 dB total isolation
Test report Nº: 086146-001
Objetive: Fire Resistance Test
Quality Standars: EN 1363-1:2020, EN 1364-1:2015 y EN 13501-2:2016
Laboratory: TECNALIA (Azpeitia – Guipúzcoa)
Date: 23 October 2020
Sample: SENOR+CHOVA EI120 SELF-SUPPORTING ACOUSTIC WALL LINING
Samples dimensions: 3 m width x 3 m height
Test duration: 149 minutes. An insulation failure occurs at minute 140 and an integrity failure occurs at minute 148.
Description of the sample: self-supporting acoustic wall lining formed with dampers SE-4800/TDM (SENOR) + dampers SE-TAV-500/11A and 11R (SENOR) + acoustic band SE-BEC-6×100 and SE-BEC- 10×100(SENOR) + 48 mm channels and studs + 4 cm CHOVANAPA absorbent material (CHOVA) + 25 mm fire-retardant PYL (KNAUF) + 4 mm VISCOLAM 65 acoustic plate (CHOVA) + 25 mm fire-retardant PYL (KNAUF)
Field of direct application (changes or variants permitted):
– WIDTH: unlimited
– HEIGHT: up to 1 metre longer than the test sample, that is, up to 4 metres.
– Further permitted variants are listed in the Classification Report.
Note: The soundproofing results obtained in this test are also valid for the TAV/500 11 A product, as both products share the same properties
Result: Fire resistance classification: EI120 E120
Fire resistance test according to EN 1364-1:2015
Qualification fire resistance test according to EN 13501-2:2016

Sample Project
INSTALLATION CERTIFICATION – ACOUSTIC PARTITION WALL

Constructive detail
With our interactive video you can ask us what you need, we will answer you as soon as possible!
ACTUAL PHOTOS
To help you
Need more help?
WE WILL BE IN TOUCH WITH YOU AS SOON AS POSSIBLE
Related products
CERTIFICATE ISO 9001
SENOR guarantees through its international certificate that we comply with quality standards, being an organization with an effective quality management system, identifying areas for improvement and taking measures to progress in them. Our goal is to provide the best service to our customers.


Designed for walls and floors

> 12 dB