The rubber damper with settling stops for acoustic raised access floors or inertia bases

REJECT IMITATIONS, BUY ORIGINAL QUALITY IS NOTICED IN EVERY DETAIL
REJECT IMITATIONS, BUY ORIGINAL QUALITY IS NOTICED IN EVERY DETAIL

Patented

Model TS-60

This innovative Elastomeric Damper is specifically designed to guarantee peace of mind in environments where intense activity generates impact noise and vibrations, such as in the case of cinemas, theaters, auditoriums, gyms and crossfit rooms. The TS-60 model offers a greater height to increase the air cavity, which in turn allows the incorporation of a higher volume of sound-absorbing material.In this way, it is possible to distance the acoustic package even further from the original structural floor slab, increasing acoustic insulation in a proportion that can be two to three times more effective compared to traditional systems of lower height.
 

OPTIMIZE YOUR SPACES WITH EXCEPTIONAL ELASTICITY AND ACOUSTIC INSULATION IN A SINGLE COMPONENT!


¡THE MOUNT THAT MAKES THE DIFFERENCE FOR HEAVY FLOORS!


Its trapezoidal design, featuring four inward-directed indentations, forms an X-shape that exponentially increases its internal elasticity. This modification not only enhances its performance in noise treatment but also promotes proper seating across a wide variety of surfaces. The new KRAIBURG-TPE composition results in a damping factor superior to that of conventional polymers such as polyurethane, polystyrene, or EPDM. This advanced material provides a durability and effectiveness in acoustic insulation that sets it apart in the market.


There are three references, each designed to support different load ranges and available in distinct colors: Green, Blue and Red.

TS-60 V 150 (Load range from 35 – 200 kg)

TS-60 A 280 (Load range from 150 – 280 kg)

TS-60 R 400 (Load range from  270 – 400 kg)


It is recommended with concrete mortar more than 50 mm thickness.

It is a RUBBER mount for concrete floors


Here you can download the installation manual

descargar Installation manual TS-60

Product registered in the Spanish Patents and Trademarks Office

It has two control movements stops in its base which allow a better installation on the ground

Easy and fast installation

Excellent soundproofing results in impact noise



SE-TS-60 V 150/25: 25 units

SE-TS-60 A 280/25: 25 units

SE-TS-60 R 400/25: 25 units

Test Report Nº: B2022-LACUS-IN-176 A
Purpose: Airborne Soundproofing Test AND Impact Noise Insulation Test
Standards: UNE-EN ISO 10140-1:2022, 10140-2:2022 and 10140-3:2022
Laboratory: TECNALIA (Vitoria, SPAIN)
Date: 15 June 2022
Sample: CHOVA+SENOR CONCRETE ACOUSTIC FLOOR
Standardised Base Floor: Reinforced concrete slab
Standardised Base Thickness and Weight: 15 cm and 375 kg/m²
Total Acoustic Floor Thickness: 12.6 cm
Sample Description: Concrete acoustic flooring system comprising: SE-TS-80 V 150 dampers (SENOR) + SE-BEC-15×170 acoustic strip (SENOR)
+ 4 cm CHOVANAPA sound-absorbing material (CHOVA) + 16 mm MDF board + CHOVACUSTIC 65 FIELTEX multilayer component (CHOVA) + 6 cm reinforced concrete

Note: For the TS-60 product, the acoustic results obtained in this test are also valid, since both products share properties.


Result: An improvement of 13 dB in airborne sound compared to the base floor, which has a rating of 59 dB, resulting in a total soundproofing of 72 dB.

Result: Reduction of 37 dB in impact noise compared to the base floor, which has a rating of 76 dB, achieving a total soundproofing of 36 dB.


descargar Laboratory measurement of airborne sound insulation and impact sound insulation improvement – WITH DAMPERS –

Construction detail

With our interactive video you can ask us what you need, we will answer you as soon as possible!

ACTUAL PHOTOS

To help you

Need more help?

WE WILL BE IN TOUCH WITH YOU AS SOON AS POSSIBLE

    Este sitio está protegido por reCAPTCHA y se aplican la Política de privacidad y los Términos de servicio de Google.

    Related products

    CERTIFICATE ISO 9001

    SENOR guarantees through its international certificate that we comply with quality standards, being an organization with an effective quality management system, identifying areas for improvement and taking measures to progress in them. Our goal is to provide the best service to our customers.

    +

    Designed for acoustic floors

    dB

    Senor
    Privacy Overview

    This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.