SENOR-TS-80/I
Click and move


Patented
TS-80/I incorporates 2 PATENTED movement and translation control stoppers in its base. Its trapezoidal design, with four indentations towards its interior forming an X-shaped figure, exponentially improves its internal elasticity, providing greater performance in the acoustic field and favouring perfect seating on the ground, obtaining acoustic improvements to impact noise of more than 37 dB, with results already tested.
There are 3 references differentiated by load range and colour:
* TS-80 V 150/I (Load range 30 – 150 kg)
* TS-80 A 280/I (Load range 140 – 280 kg)
* TS-80 R 400/I (Load range 250 – 400 kg)
✓ Recommended for application with concrete mortar thicker than 50 mm.
Installation video
It is a different and renewed, high-performance RUBBER damper. Recommended for raised floors under reinforced concrete slabs.
Laboratory measurement of airborne sound insulation and impact sound insulation improvement – WITH dampers –
Here you can download the installation manual
Product registered in the Spanish Patents and Trademark Office.
Its design favours a perfect settlement on the ground.
Its base incorporates 2 movement control stops
Quick and easy to install
Excellent results at impact noise


Load range:: 30-150 kg
Load range: 140-280 kg
Load range: 250-400 kg

Resonance Frequency: 7 – 15 Hz

Format de boite:
– SE-TS-80 V 150/16-I: 16 uds
– SE-TS-80 A 280/16-I: 16 uds
– SE-TS-80 R 400/16-I: 16 uds
Test Report Nº: B2022-LACUS-IN-176 A
Purpose: Airborne Soundproofing Test AND Impact Noise Insulation Test
Standards: UNE-EN ISO 10140-1:2022, 10140-2:2022 and 10140-3:2022
Laboratory: TECNALIA (Vitoria, SPAIN)
Date: 15 June 2022
Sample: CHOVA+SENOR CONCRETE ACOUSTIC FLOOR
Standardised Base Floor: Reinforced concrete slab
Standardised Base Thickness and Weight: 15 cm and 375 kg/m²
Total Acoustic Floor Thickness: 12.6 cm
Sample Description: Concrete acoustic flooring system comprising: SE-TS-80 V 150 dampers (SENOR) + SE-BEC-15×170 acoustic strip (SENOR)
+ 4 cm CHOVANAPA sound-absorbing material (CHOVA) + 16 mm MDF board + CHOVACUSTIC 65 FIELTEX multilayer component (CHOVA) + 6 cm reinforced concrete
Result: An improvement of 13 dB in airborne sound compared to the base floor, which has a rating of 59 dB, resulting in a total soundproofing of 72 dB.
Result: Reduction of 37 dB in impact noise compared to the base floor, which has a rating of 76 dB, achieving a total soundproofing of 36 dB.
Laboratory measurement of airborne sound insulation and impact sound insulation improvement – WITH DAMPERS –
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Sample Project
Calculation of hybrid supports for roof-mounted equipment on an acoustic platform.
ACTUAL PHOTOS
To help you




Need more help?
WE WILL BE IN TOUCH WITH YOU AS SOON AS POSSIBLE
CERTIFICATE ISO 9001
SENOR guarantees through its international certificate that we comply with quality standards, being an organization with an effective quality management system, identifying areas for improvement and taking measures to progress in them. Our goal is to provide the best service to our customers.


Exclusive For Acoustic Floors

dB